Commercial, Residential

MCWD SLIM: Parkair’s 2026 novelty for retrofits

One of the main considerations for anyone evaluating the purchase and installation of an air conditioning system with no outdoor unit is certainly the choice between a monobloc system and a split system. The two configurations meet many different needs, but they share one element in common: the absence of the outdoor motor on the building’s façade.

The entire Parkair product range is identified as air conditioning systems with no outdoor unit, whether monobloc or split systems. The monobloc integrates everything into a single unit; the split system, on the other hand, consists of an indoor motor connected to fan units. The choice depends on the available space, the number of rooms to be conditioned and any architectural constraints.

Monobloc vs split with no outdoor unit

One of the main considerations for anyone evaluating the purchase and installation of a air conditioning system with no outdoor unit is certainly the choice between a monobloc system and a split system. The two configurations meet many different needs, but they share one element in common: the absence of the outdoor motor on the building’s façade.

What’s the difference between monobloc and split?

The monobloc houses all components, compressor included, in a single unit. There are two variants, designed for different needs: a room unit, installed directly in the room to be conditioned, and a ducted version, installed in a plant room or false ceiling and connected to multiple rooms through hidden ducting.

The room-unit variant, AiROCK Acqua and AiROCK Aria, comes pre-charged with refrigerant gas from the factory: for this reason, neither model requires F-Gas certification for installation. What does change is what needs to be connected to make them work: AiROCK Acqua connects to the water mains and the power supply, with no work needed on the wall; AiROCK Aria, on the other hand, must be fixed to a wall that leads to the outside, since it requires two openings for the air exchange grilles, in addition to the electrical connection.

The ducted variant, MCWD SLIM, follows a different logic: it is installed in a plant room or false ceiling, and distributes air to multiple rooms through hidden ducting. Thanks to its compact structure, only 30 cm high, it is the ideal choice where installation space is particularly limited, designed for residential settings.

The split system, on the other hand, is closer to the classic structure of traditional air conditioners, separating the indoor fan unit from the condensing unit and connecting the two parts with refrigerant pipework. The key difference is that the condensing unit is still positioned inside the building: this is the case for MCW 2.0 and MCA 2.0. In neither architecture, monobloc or split, does a component appear on the façade as it would with traditional air conditioners.

The condensing unit of Parkair split systems is installed in a plant room, false ceiling, under-stairs space, cabinet or built into furniture, depending on the range. The only real distinction concerns the type of technology, Water/Air or Air/Air: in the first case, the unit can be positioned anywhere a water connection is available; in the second, a connection to the outside of the building must be provided, an operation comparable to that required for installing AiROCK Aria.

Technical specifications

PRK-MCWD-12 PRK-MCWD-18
Cooling / heating capacity 3.5 / 3.7 kW 5.2 / 5.2 kW
EER / COP 4.38 / 4.46 W/W 4.19 / 4.46 W/W
Energy class A++/A+ A++/A+
Refrigerant R32 R32
Absorbed power (cooling / heating) 0.80 / 0.94 kW 1.24 / 1.17 kW
Airflow 700 m³/h 850 m³/h
Static pressure 50 Pa 125 Pa
Average water consumption (cooling / heating) 100 / 128 l/h 128 / 195 l/h
Sound pressure / sound power 44 / 56 dB(A) 47 / 57 dB(A)
Dimensions 1152x579x300 mm 1152x579x300 mm
Weight 45 kg 52 kg
Power supply Single-phase Single-phase

Functions common to both sizes: cooling, heating, dehumidification, ventilation. Installation in a plant room or false ceiling, also suitable for Water Loop (WLHP) applications.

Where can it be installed?

MCWD SLIM, in both sizes, is designed for residential, hospitality (HoReCa), commercial, office and boutique applications, as well as server rooms. It complies with local building and condominium regulations, and requires no work on the façade: no grilles, no openings, no visible outdoor unit.

FAQ

 

Q: How does MCWD SLIM differ from MCWD?

A: MCWD SLIM is the compact version of the range, only 30 cm high and available in two sizes from 3.5/3.7 to 5.2 kW, ideal where false ceiling height is limited. MCWD covers higher outputs, in three sizes (PRK-MCWD-32, 48 and 60, corresponding to 10, 15 and 18 kW), for larger commercial settings.

Q: What is the difference between PRK-MCWD-12 and PRK-MCWD-18?

A: PRK-MCWD-12 delivers 3.5 kW in cooling and 3.7 kW in heating, with lower consumption and noise levels. PRK-MCWD-18 reaches 5.2 kW in both modes, with higher airflow and static pressure, suited to larger rooms or more demanding ducting.

Q: Does it require work on the façade?

A: No. Installation is entirely indoors, in a plant room or false ceiling: no openings, no grilles, no visible outdoor unit, for both sizes.

Q: Is it also suitable for listed buildings or historic centres?

A: Yes. Being compliant with local building and condominium regulations and free of any external element, it is well suited to settings with architectural or landscape restrictions.

MCWD SLIM brings the comfort of ducted air conditioning even where false ceiling space is limited, without any work on the façade. Find out if it’s the right solution for your project: Catalogue 2026